松元 佳嗣

Matsumoto Yoshitsugu

  • 講師
  • 学位:博士(医学)

基本情報

所属

  • Undergraduate School of Medicine / Faculty of Medicine

詳細情報

研究キーワード

  • Radiotherapy

論文

Clinical outcomes and prognostic factors of volumetric modulated arc therapy (VMAT) of esophageal cancer.

Factors Involved in the Choice Between Thoracic and Abdominal Deep Inspiration Breath Holds During Left Breast Cancer Radiotherapy.

Effect on Heart and Lung Doses Reduction of Abdominal and Thoracic Deep Inspiratory Breath-hold Assuming Involved-field Radiation Therapy in Patients with Simulated Esophageal Cancer.

Dose and organ displacement comparisons with breast conservative radiotherapy using abdominal and thoracic deep-inspiration breath-holds: A comparative dosimetric study.

Examination of the dose distribution of volumetric modulated arc radiotherapy using a high-definition multi-leaf collimator for breast cancer patients with irradiated regional lymph nodes

Comparing the toxicity and disease control rate of radiotherapy for prostate cancer between salvage settings after high-intensity focused ultrasound therapy and initial settings.

Dosimetric study of whole-brain irradiation with high-energy photon beams for dose reduction to the scalp.

Basic evaluation of a novel 4D target and human body phantom.

[Verification of the protective effect of a testicular shield in postoperative radiotherapy for seminoma].

[Verification of the dose from an iridium-192 ((192)Ir) sealed source absorbed by an implantable cardioverter defibrillator (ICD) during uterine intracavitary brachytherapy].

Study of third-party evaluation of the output dose of external radiation therapy equipment in Fukuoka Prefecture

A new phantom using polyethylene glycol as an apparent diffusion coefficient standard for MR imaging

In vitro experimental study of the relationship between the apparent diffusion coefficient and changes in cellularity and cell morphology

講演・口頭発表等

  • Dose comparison of tangential irradiation using abdominal and thoracic DIBH for radiotherapy after left breast conserving surgery.
  • Examination of the dose distribution of VMAT using a HD-MLC for breast cancer patients with irradiated regional lymph nodes
  • Automated contour correction of deep learning-based sphere-shaped contour errors
  • Automatic Detection of Circular Contour Errors Using Convolutional Neural Networks
  • A case of radiotherapy for skin lesions of blastic plasmacytoid dendritic cell tumor
  • Effect of breathing method on central lung distance and maximum heart distance during breath-hold irradiation after left breast conserving surgery
  • Comparison of VMAT and 3DCRT for postoperative radiotherapy including lymph node using HD 120 MLC
  • Verification of target movement using a new 4-dimensional target-moving phantom.
  • Basic evaluation of target movement using 4-dimentional target-moving phantom.
  • Evaluation of SBRT dose using novel 4-dimensinal target-moving phantom.
  • 精上皮腫に対する放射線治療時に用いる睾丸シールドの有効性の検討
  • 精巣腫瘍に対する放射線治療時における睾丸シールドの有効性の検討
  • 全脊髄照射における脊髄部のギャップ確認方法の考案
  • IMRTにおける手計算による検証方法の改良 -各照射セグメントから線量評価点への線量寄与率を用いる方法-
  • IMRTにおける手計算による検証方法の開発 -各照射セグメントから線量評価点への線量寄与率を用いる方法-

共同研究・競争的資金等の研究課題

Development of objective evaluation method for radiation pneumonitis

Target position prediction system by machine learning corresponding to various irregular breathing patterns

ResearchMapへ移動します

Contact Us

Inquiries about coverage

Public Affairs Division Public Affairs and Communications Department

Tel. 0463-63-4670(direct dialing)